Skip to content
Catalyst

PapersPMID:37944507

Effect of Personalized Sodium Replacement on Fluid and Sodium Balance and Thermophysiological Strain During and After Ultraendurance Running in the Heat.

International journal of sports physiology and performance2024The record ↗

findings
3
compound
1
endpoints
3
no difference found
2
PMID:37944507
  1. Finding, very limited evidenceraisesSerum sodium concentration
  2. Finding, very limited evidenceno difference foundCore body temperature
  3. Finding, very limited evidenceno difference foundRating of perceived exertion
Study, every finding
crossover
Dose studied, every finding
sodium chloride capsules replacing 100% of previously assessed sweat sodium losses, during a 5-hour run; placebo comparator
  • “Plasma sodium concentration increased in both trials, but to a greater extent in SODIUM at 2.5 hours (mean [SD]: 4 [4] mmol·L-1 vs 1 [5] mmol·L-1; P < .05) and postexercise (4 [3] mmol·L-1 vs 1 [5] mmol·L-1; P < .05).”
    Population
    Nine healthy participants (7 male, 2 female) during two 5-hour treadmill runs in the heat; change in plasma sodium at 2.5 hours and postexercise

What did not

Study record

Design
crossover trial
Species
human
Population
Nine participants (7 male, 2 female) completing two 5-hour treadmill runs in the heat
Participants
9
Comparator
placebo
Duration
not reported
Endpoints measured
13